Illuminating/viewing system: | d/8 (diffused illumination, 8-degree viewing angle), equipped with simultaneous measurement of SCI (specular component included) / SCE (specular component excluded). |
| (Conforms to DIN 5033 JIS Z 8722 Condition C,ISO 7724/1, CIE No.15, ASTM E1164.) |
Size of integrating sphere: | Ø 52mm |
Detector: | Silicon photodiode array (dual 40 elements) |
Spectral separation device: | Diffraction grating |
Wavelength range: | 360nm to 740nm |
Wavelength pitch: | 10nm |
Half bandwidth: | Approx. 10nm |
Reflectance range: | 0 to 175%, Display resolution: 0.01% |
Light source: | 3 pulsed xenon lamps (2 xenon lamps for CM-2500d) |
Measurement time: | Approx. 1.5 seconds (approx. 2 seconds for fluorescent measurement) |
Minimum measurement interval: | 3 seconds for SCI/SCE (4 seconds for fluorescent measurement) (Simultaneous evaluation of SCI/SCE is possible by a single measurement) |
Measurement/illumination area: | MAV: Ø 8mm/ Ø11mm SAV: Ø 3mm/ Ø 6mm (Selectable between MAV and SAV) (Only MAV is available for CM-2500d) |
Repeatability | (Standard deviation): Spectral Reflectance: within 0.1% (360 to 380nm within 0.2%) Chromaticity Value : Delta E*ab within 0.04 (When white calibration plate is measured 30 times at 10-second intervals after white calibration) |
Inter instrument agreement: | Delta E*ab within 0.2 (MAV/SCI) (Based on 12 BCRA Series II color tiles compared to values measured with master body) |
UV adjustment: | Instantaneous adjustment (without mechanical moving parts) with UV400nm cut filter |
Measurement mode: | Single/averaging (auto mode: 3, 5, 8 flashes/manual mode) |
Interface: | RS-232C |
Observation: | 2/10 degrees |
Observation light source: | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources |
Outputs: | Spectral value/graph, colorimetric value, color difference value/graph, PASS / FAIL result |
Color space/colorimetric data: | L*a*b, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, DIN99 XYZ, Yxy, Munsell, MI WI (ASTM E313), WI / Tint (CIE, Ganz/Griesser) YI (ASTM E313/ASTM D1925), ISO Brightness (ISO 2470) Density status A/T |
Storable data sets: | 700 (SCI/SCE as a set) |
Tolerance judgment: | Tolerance for color difference (both box and elliptical tolerances can be set) |
Power: | AA-size battery (x4), Rechargeable batteries, AC adapter |
Battery performance: | Approx. 1000 times at 10-second intervals (when alkaline batteries used |
Size (WxHxD): | 69 x 96 x 193mm |
Weight: | Approx. 670g (without batteries) |
Operating environment: | 5 to 40°C; less than 80% RH (no condensation); Installation category: 2; Pollution degree: 2 |
Storage environment: | 0 to 45°C; less than 80% RH (no condensation) |
Standard accessories: | White calibration plate, Target mask Ø 8mm, Target mask Ø 3mm (not supplied for CM-2500d), RS-232C cable, AC adapter, 4 Type AA batteries |